Pressure reducing filter combination, Figure 713 0G
Product features
Mechanically acting, manual backwash filter
Pressure regulator with pressure-relieved single-seat valve and inlet pressure relief
Internal parts made of gunmetal, Stainless steel and plastic
Automatic differential pressure-controlled indicator when the filter is dirty
Opaque filter bowl to protect against algae build-up
with connection flange and high-quality gunmetal control unit for the backwash and drain process and draining process
Valve housing of the pressure reducer made of transparent plastic
Outlet pressure can be individually adjusted using the lockable plastic adjustment wheel with indicator scale
Pressure reducer completely serviceable
Integrated stainless steel dirt trap on the inlet side External threadStrainer
External thread for flat-sealing screw connections
Filter insert completely replaceable
Rotatable drain device in accordance with DIN EN 1717
Free of dead space
Horizontal and vertical installation position, Drain valve at the bottom
Monthly maintenance indicator to maintain the backwash intervals
Incl. Pressure gauge for backwash pressure
incl. hexagon spanner
incl. gunmetal base module
the maintenance requirement acc. DIN EN 806-5 must be observed
Standards and approvals
DVGW approval
Plastic parts with KTW approval
in accordance with UBA assessment basis
up to DN 32 Sound insulation approval in accordance with DIN EN ISO 3822 class 1
DIN EN 1213 / DIN EN 13443 / DIN EN 1567
Technical data
Pressure rating PN 16
Max. operating temperature 30 °C
Min. inlet pressure 0.2 MPa Inlet pressure 0.2 MPa
min. Outlet pressure 0.15 MPa
max. Max. outlet pressure 0.60 MPa
Factory default setting 0.4 MPa
Lower passage width 90 µm
Upper passage width 125 µm
KEMPER pressure reducing filter combination, figure 713 0G, mechanically acting, manual backwash filter, pressure regulator with pressure-relieved single-seat valve and inlet pressure relief, Internal parts made of gunmetal, stainless steel and plastic, automatic differential pressure-controlled indicator when the filter is dirty, opaque filter bowl to protect against algae build-up, with connection flange and high-quality gunmetal control unit for the backwash and drain process, Valve housing of the pressure reducer made of transparent plastic, outlet pressure individually adjustable on lockable plastic adjustment wheel with display scale, pressure reducer completely serviceable, integrated stainless steel dirt trap on the inlet side, external thread for flat-sealing screw connections, filter insert completely replaceable, rotatable drain device in accordance with DIN EN 1717, free of dead space, horizontal and vertical installation position, drain valve at the bottom, monthly maintenance indicator to maintain the backwash intervals, incl. pressure gauge for outlet pressure, incl. pressure gauge for outlet pressure, incl. pressure gauge for outlet pressure, incl. pressure gauge for outlet pressure, incl. pressure gauge for outlet pressure, incl. pressure gauge for outlet pressure, incl. pressure gauge for outlet pressure, incl. pressure gauge for outlet pressure, incl. pressure gauge for outlet pressure. Pressure gauge for outlet pressure, incl. hexagon spanner, incl. gunmetal base module, DVGW approval, plastic parts with KTW approval, in accordance with UBA assessment basis, up to DN 32 sound insulation approval in accordance with DIN EN ISO 3822 class 1, DIN EN 1213/DIN EN 13443/DIN EN 1567, pressure rating PN 16, max. operating temperature 30 degrees C, min. inlet pressure 0.2 MPa, min. outlet pressure 0.15 MPa, max. outlet pressure 0.60 MPa, max. outlet pressure 0.60 MPa, min. inlet pressure 0.2 MPa, min. outlet pressure 0.15 MPa, max. outlet pressure 0.60 MPa. Outlet pressure 0.60 MPa, factory presetting 0.4 MPa, lower passage width 90 My, upper passage width 125 My, Note: the maintenance requirements in accordance with DIN EN 806-5 must be observedInstruction for use
:
KEMPER products may only be installed by trained specialist personnel in compliance with the applicable standards and guidelines