With 4 independent contacts, 1 NO contact each potential-free 16A/250V AC, 230V LED lamps up to 600W, incandescent lamps 2000W. Stand-by loss only 0.03-0.4 Watt. Modular device for mounting on DIN-EN 60715 TH35 rail. 2 pitch units = 36mm wide, 58mm deep. With the patented Eltako Duplex technology (DX), 3 of the 4 normally potential-free contacts can still switch in zero crossing when switching 230V AC 50Hz, thus drastically reducing wear. To do this, simply connect the N conductor to the terminal (N) and the outer conductors to 1 (L), 3 (L) or 5 (L). This results in an additional stand-by loss of only 0.1 Watt. If the contact is used to control switchgear which itself does not switch in zero-crossing, (N) should not be connected, as the additional closing delay will otherwise have the opposite effect. Local universal control voltage 8..230V UC. With additional universal voltage control inputs centrally on and off for 8..230V UC, galvanically isolated from the local control inputs. With additional group control inputs on and off for 8..230V UC. Same potential as the local control inputs. Groups of these impulse switches can be controlled separately in a central control system via the group control inputs. Same supply voltage as the local control voltage. Due to the use of bistable relays, there is no coil power loss and no heating even when switched on. After installation, wait for the automatic short synchronisation before connecting switched loads to the mains. Central commands always have priority, the local control inputs are blocked during the central command. In the event of a supply voltage failure, defined is switched off. With the upper rotary switch, this impulse switch can be completely or partially excluded from central control: ZE+ZA = central on and central off effective, ZE = only central on effective, ZA = only central off effective, ZE+ZA crossed out = no central control effective. With the middle rotary switch, the functions of the lower rotary switch are preselected for ES and ER. The clamp functions are selected with ER. If BM is selected, it can be controlled with a motion detector, function according to the operating instructions. Not suitable for feedback with the switching voltage of a dimmer switch. Only use the relays ESR12DDX-UC, ESR12NP-230V+UC or ESR61NP-230V+UC for this purpose. The lower rotary switch can be used to select between 18 functions.
There are no reviews yet.