Choose your country of delivery to see prices and products for your location.
Choose tax zone / country of delivery
- On gas, Water and waste water pipes- Load test up to 1000 hPa- Leak test with 150 hPa according to TRGI2018- Propane gas test with 100 hPa according to TRF96- Leak detection according to TRGI2018- Water leakage test with external pressure sensor (optional)- Water strength test with external pressure sensor (optional)- Sewer leakage test according to DIN EN 1610 (air method) - Flow pressure measurement up to 300 hPa - All measurements can be documented on site using the built-in needle printerLeak test in accordance with DIN EN 1610 (air method)- Flow pressure measurement up to 300 hPa- All measurements can be documented on site using the built-in dot matrix printer- Date and time set directly via TOUCH display- Owner and inspector details on the printout- The pump automatically builds up the correct test pressure for each function- Pressure range: -650 to +1500 hPa- Water set pressure range: 0.15 to 20 bar (optional)- Accuracy: <1% FSO / ext. Pressure sensor <4% FSO- Resolution: 0.1 hPa / ext. Pressure sensor 0.01 bar- Operating time with battery: 20 to 30 hours- Needle printer: 45 mm normal paper- Scope of delivery:- digital leak tester with integrated dot matrix printer- Mains charger- Plastic case- Touch pen- Silicone hose for burner/flow pressure- Replacement paper roll- Test hose with pneumatic couplings- Test piece conical PSP1 Test piece conical PSP1 (19-32 mm)- Test piece conical PSP2 (24-44 mm)- Test piece cylindrical ZPP 1" - Test piece cylindrical ZPP 3/4"- Single-tube meter cap ERZP32 (for G4/G6)- Y-hose adapter