The valve can be installed both horizontally and vertically as well as in an inverted position. The thermowell of the temperature sensor supplied with the valve must be installed on the flow pipe at a distance < 0.5 m from the heat generator or at the highest point of the boiler and in any case before the drain pipe. The thermowell supplied with the valve must be used.- Used with double sensor protection as a safety device in heating systems that use a thermal cooker or a thermal chimney as a heat generator. The device combines a thermal drain safety device and a filling valve in a single block, which are activated simultaneously when controlled by a remote sensor with positive safety.Technical data:- Fixed setting: 100°C- Temperature range: 5 ... 110°C- Operating pressure: max. 6 bar- Immersion sleeve: DN15 (1/2")- Capillary tube length: 1.3 m