Choose your country of delivery to see prices and products for your location.
Choose tax zone / country of delivery
No, I do not want a free functional warranty extension. I will not send my old, defective item back to Heiz24.
incl. 19% VAT , Free shipping to DE. shipping costs
• Logamatic 5311 controllerModular, digital controller for professional applications in the medium andlarge output range. Use as a control device for Boiler systems with burner control for 1stage, 2stage with/without startup relief and modulating burners via conventional burner plug Function extensions Substations Standalone applications Flexible installation on the boiler, laterally or on the wall Simple wall mounting via rear housing part incl. cable guide Cable routing and strain relief Quick and easy installation thanks to large connection compartment with good accessibility Can be extended with function modules from the Loga matic 5000 system via 4 free module slots Internal communication via data bus Logalux FS fresh water stations and Logasol solar thermal systems can be integrated via the SM100 function module Simple system expansion for components required on site B. Relays) can be integrated via a tophat rail Basic configuration consists of ZM5311 central module, NM582 mains module with on/off switch and 2 separate fuse circuits (boiler/burner, System) as well as the burner control unit and all basic functions Operating unit/controller module BCT531 with capacitive touch operation Controller module with 2 USB ports s, SD card slot and 2 Ethernet interfaces External temperature sensor Boiler water temperature sensor 2nd stage burner cable Safety equipmentStage Safety equipment, component with adjustable electrical tronic safety temperature limiter STB99/110 degrees C Input for switching the operating conditions and burner type when using dualfuel burners Flue gas shutoff damper connection Protection of the operating unit during the construction phase by easy removal Protection class IP 40 Coded and colourcoded, dulBasic functions Control of 1 and 2stage burners via contacts stage1, stage2 Control of modulating burners optionally via 3point step controller or 020mA or 420mA power control or 010V signal Ensuring specific operating conditions through boiler circuit control with actuator and demandbased control of the boiler circuit pump Powercontrolled or temperaturedif frequencycontrolled speed control for the boiler circuit pump via 010 V output "FlowControl" Control of a heating circuit with/without actuator and heating circuit pump (only as an alternative to the boiler circuit function) with the option of connecting a remote control (BFU) Control of a feeder pump for a substation:• The feeder pump can be connected either to the master controller (module FMMM/FM MW required) or to the substation (terminal PK on the central module ZM5311) To reduce the heat losses in the feeder pipe, the feeder circuit can be equipped with a mixer made of Control of a hot water circuit with storage tank charging pump and circulation pump Optional thermal disinfection of the hot water circuit Automatic adjustment of the setback temperature to the setback temperature Automatic adjustment of the lowering temperature in accordance with DIN EN 12831 for heating circuits can be set separately Time programme Holiday mode with freely selectable lowering function Summer/winter time changeover Seasonal timerOperation Operating status via status display as easily recognisable from a distance via large LED strips Highquality and robust capacitive 7" touch screen with highresolution display for parameterisation, and display of all controller data Simple and selfexplanatory operation and display and in hydraulic representations Can be switched to "retro mode" for heating circuits and hot water for operation analogue Logamatic 4000 Manual operating levels for all system components (example:• Pump on/off, heating circuit switching option off/automatic/manual) Buswide operation of the entire system from one control device/point USB port for service purposes (USB IP adapter required, Accessory) No service software required Longterm data recording via SD card (provided by customer) possible Software update via USB stick possibleConnectivity Simple connection w. other control devices of the Logamatic 5000 via Ether net interface Simple connection to thirdparty systems via standard On/off contact Contact for external interlocking Contact for external locking 010 V input Collective signal Simple connection to building control nik via standard MODbus TCP/IP interface IPInside:• Ethernet interface for monitoring and adjusting the userrelevant parameters via the Internet (Control Centre Commercial) in the 1:• 1 presentation of the touch screen. This requires the conclusion of a separate contract for the use of Control Cen ter Commercial. The use of is currently free of charge, in accordance with the current terms of use and service description in the portal (subject to changes). Professional remote data transmission with full remote parameterisation and many other functions via gate way (optional, accessory) and portal use (Control Center CommercialPLUS, subject to a charge). This requires the conclusion of a separate contract ber for the use of Control Center CommercialPLUS. Prices in accordance with the current terms of use and service description in the portal (subject to change without notice). Dimensions W/H/L:• 652/274/253 mmEU DIRECTIVE FOR ENERGY EFFICIENCYTemperature controller class:• IIContribution of the temperature controller to seasonal room heating energy efficiency:• 2.0 %Buderus article no.:• 8718592475 Buderus article no.:• Buderus article no.:
There are no reviews yet.