Choose your country of delivery to see prices and products for your location.
Choose tax zone / country of delivery
Outdoor unit - Ideal for refurbishment- For heating and cooling operation- Eligible for subsidies according to BEG- Operation with refrigerant R410A- Inverter capacity control, double rotary piston compressor- Intermediate circuit injection- Flow temperature up to 60°C- Heat pump heating operation down to -25°C- Operating voltage: 400 VIndoor unit:- Coaxial copper tube heat exchanger for safe and efficient operation- Integrated heating element: 9 kW- Highly efficient circulation pump - Weather-compensated control- Indoor unit completely pre-assembled, for wall mounting- Safety devices: Expansion vessel (10 l), pressure gauge, safety valve
Type
LWP HP ECO
15
17
EEK Space heating low temperature
A+++ to D
A++
EEK Room heating medium temperature
Heating output /COP according to EN 14511 - with A2/W35 rated output - with A7/W35 rated output - with A-7/W35 rated output
- - - RATED OUTPUT
9.4 / 4.19 6.7 / 5.13 15.4 / 2.9
9.7 / 4.1 6.8 / 5.01 16.0 / 2.8
Dimensions outdoor unit (W x H x D)
[mm]
1080 x 1428 x 515
Dimensions indoor unit (W x H x D)
448 x 842 x 477
Weight outdoor unit
[kg]
138
Weight indoor unit
53
Ref. no.
524867
524868